Alat infusion pump ini merupakan alat untuk mengatur jumlah cairan / obat yang masuk kedalam sirkulasi darah pasien secara langsung melalui vena. Kami menyediakan alat ini dalam kondisi baru. Untuk Info selengkapnya silahkan cek spesifikasi produk. Terima kasih telah berkunjung di website ini dan selamat berbelanja.
Spesifikasi Produk :
(harga dan spesifikasi dapat berubah tanpa pemberitahuan terlebih dahulu demi penyempurnaan produk)
(dilarang memakai spesifikasi berikut untuk tender/pengadaan tanpa konsultasi/konfirmasi kepada gesunde medical)
Kode SKU : (kode stok internal, bukan kode produk) | GM-27290 |
Model : | Optima VS Flowrate 1-1000ml/H |
Jenis : | Infusion Pump |
Merk : | FRESENIUS KABI |
PERFORMANCES | |
Flow Rate Range : | 1 to 1000 ml/h in normal mode (or up to 1500 ml/h***), 1 ml/h increments. 0.1 to 100 ml/h in micro-infusion mode, 0.1 ml/h increments |
Flow Rate Accuracy : | ±5% with recommended sets |
Volume Range : | 1 to 9999 ml in normal mode (1 ml increments) 0.1 to 999.9 ml in micro-infusion mode (0.1 ml increments) |
Infusion Time : | Adjustable from 1 minute to 96 hours (1 min increments) |
Setting Modes : | Flow rate only, flow rate + volume, volume / time, rate + time, ramp-up / ramp-down, primary/ secondary, sequential, bolus, induction / loading dose, micro-infusion |
OCS* Occlusivity Check System : | The patented OCS test is the only auto-test to check the good operating og the pump in association with its set thus preventing all risk of free-flow |
KVO Rate : | 3 ml/h adjustable |
Pressure Limit : | 750 mmHg, adjustable from 100 to 900 mmHg (50 mmHg increments) |
Pause Function : | Adjustable from 1 minute to 24 hours |
History Module : | Up to 764 last dated events |
Configuration : | Infusion modes (micro or macro-infusion), ramp-up / ramp-down, sequential, induction, bolus, primary / secondary, keybord lock, KVO pressure limit, display of drug name, time and hour setting, language, LCD contrast, alarm sound level, ward name, maximum authorized flow rate air bubble size, recall of last parameters at power ON, display mode, volume cumulating, end of infusion pre-alarm setting. |
RS 232 Connection : | Bi-directional connection |
Nurse Call : | Outlet for alarm report |
Safety Features and Alarm : |
|
TECHNICAL SPECIFICATIONS | |
Pumping System : | Second generation linear wave peristaltic pimping system controlled by an intelegent software for a constant and precise flow rate |
Pumpfixation : | Optima VS can be placed onto a table, or secured to a pole or a rail with their incorporated clamps |
Compliance : | Complies with the 93/42 EEC : European Medical Device Directive CE 0459. Complies with EN 60601-1, EN 60601-1-2 and EN 60601-2-24 requirements. - Waterproofness : protection against splashing liquid IP31 - Protection aginst leakage current : Type CF equipment - Protection against electrical shocks : class 1 equipment |
Main Supply : | 100 – 240V-/50-60Hz |
Battery : | Characteristics : NiMH – 6V 2.7 / 3 Ah Battery Life : 5 h 30 in average at 125 ml/h |
Battery Charging Time : | Device off : 5 hours / Device on : 16 hours |
Drop Detector** : | Use for an empty bottle detection (optional on Optima VS) |
Housing : | In PC ABS HF, the unit is designed to reduce liquid ingress and facilitate the cleaning and disinfection. |
Dimension / Weight : (bukan untuk spesifikasi tender) | H=13.5, W=17.5, D=14.5 cm / 2.9 kg |
Harga : | Hubungi Kami |
TAG :
tempat jual infusion pump, dimana cari infusion pump, grosir infusion pump murah, harga infusion pump, agen infusion pump, infusion pump toko murah, daftar harga infusion pump, mau beli infusion pump