Kode SKU :
(kode stok internal, bukan kode produk) | GM-BI-3000 |
Jenis : | EKG/ECG (Electrocardiograph) |
Tipe : | ECG 12 channel CardioCare 3000 with SPM-300 Spirometer |
Recording Channel : | 3, 6,12 channel, 1 channel (60 sec) and beat report |
Sensitivity : | 5, 10, 20 auto (I~aVF: 10, V1~V6:5) mm/mV |
Printing Speed : | 12.5, 25, 50 mm/s |
Filters : |
- AC (50/60 Hz, -20dB or better)
- Muscle (25~35Hz, -3dB or better)
- Base Line Drift (0.1Hz, -3dB or better)
- Low pass filter (off, 40Hz, 100Hz, 150Hz)
|
Display : | 320 x 240 character LCD display (3 leads trends) |
Monitor : | Display ID, date, sensitivity, speed, filter, form, rhythm lead |
User Intefrace : | Touch screen (alphanumeric and symbol available), keyboard, rotary push-knob (pop-up menu) |
Patient Data : | ID, name, age, sex, height, weight |
Basic Measurement : | Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis |
Recorder : | Thermal print head, thermal roll paper
Report papers :
- Width: A4: 210mm or 8.5"
- Length: A4: 300mm or 11"
Effective writing width : 204mm
Resolution :
- Vertical: 8 dot/mm
- Horizontal: 16 dot/mm |
Electrical : |
- Internal noise : 20uV (p-p )max
- Input circuit : Floating input
- Isolated and defibrillation protected
- Input impedance : =10MO
- Input range : =±5mV
- Common Mode Rejection : =+100dB
- DC offset voltage : =±300mV
- Time constant : 3.2sec
- Patient leakage current : <10uA
- Frequency response 0.05~150Hz
|
Signal qualilty control : | Disconnected lead detection |
Power : |
- Power supply: AC or built-in battery (option)
- 100-240 vac, 50/60Hz, 1.0-0.5 A, 60W max
|
Battery : | (Ni-MH) 1 hour of normal use (approx. 100 ECG printouts) |
Communication : | PC connection with RS-232 interface and LAN |
Safety : | Class 1, Type BF |
Conformity : | CE, CSA |
Environment : |
- Operating humidity: 30~85%
- Operating temperature: 10° ~ 40° C
- Atmospheric pressure: 70 ~ 106 KPa
|
Standar Accessories : |
- Power Cord - 1ea.
- Patient Cable - 1 ea.
- Electrode - 10 ea.
- Chart paper - 1 ea.
- Operation manual - 1 ea.
|
Options : | Cart, Hanger, Bag, Trolley |
Measuring Values : |
- FVC: FVC, FEV 1.0, FEV 1/FVC, FEF 0.2 - 1.2L, FEF 25 - 75%
- FEF 75 - 85%, PEF, FEF 25%,
- FEF 50%, FEF 75%
- SVC: SVC, ERV, IRV, TV, EC
- MVV: MVV, FB, TV
|
Presentation : |
- Flow volume loop
- Flow time plot
- Measurment values table
|
Measuring range : |
- Flow: 0 to ±14 L/s
- Volume: 0 to ± 11L
|
Measuring method : | Differential values table |
Prediction equation : | Morris-Polgar, ECCS-Quanjer, Knudson-ITS |
Sample rate : | 200 samples/sec |
Flow impedance : | <0.2 mbar s/l at 12 l/s |
Measuring accuracy : |
- Complies with ATS
- (American Thoracic Society)
|
Environment : |
- Ambient temperature: 15 to 40°C (59 to 104°F)
- Relative humidity: 10 to 90% (non-condensing)
- Atmospheric pressure: 700 to 1060 hPa
|
Standard accessories : |
- Nose clip 1 ea.
- Adapter 2 ea.
- Operation manual 1 ea.
- Disposable mouthpiese 1 box (100 ea.)
|
Dimension :
(bukan untuk spesifikasi tender) | 47 (W) x 200 (H) x 34 (D)mm, approx. 250g |
Dimensi Packing :
(bukan untuk spesifikasi tender) | 35 x 55 x 15 cm |
Berat Volume Pengiriman : | 8 kg (pembagi 6000) 10 kg (pembagi 4000) |
Harga : | Hubungi Kami
|